Level D· Scientific groundwork from lab and animal studiesLaboratory StudyEurope PMC

Aligned Gelatin Microribbon Scaffolds with Hydroxyapatite Gradient for Engineering the Bone-Tendon Interface

Stanton AE., Tong X., Jing SL., Behn A., Storaci H., Yang F.

Laboratory Study on Tendon Injury, Ligament Injury, Rotator Cuff, published in Tissue Eng Part A (2022) — summary generated from the PubMed abstract.

Open my reading list
Level D· Scientific groundwork from lab and animal studiesEvidence level of this study

Evidence from laboratory and animal studies provides groundwork for understanding mechanisms and potential before human studies continue.

  • Level A · Stronger Clinical Evidence
  • Level B · Emerging clinical evidence with positive signals
  • Level C · Early human research exploring benefits
  • Level D · Scientific groundwork from lab and animal studies
  • Emerging · Emerging topic under active research
Read the A–D evidence level guide

This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.

Study type
Laboratory Study
Journal
Tissue Eng Part A (2022)
Reported sample size
—
Source database
Europe PMC
PMID
35229651
PMCID
PMC9469746
DOI
10.1089/ten.tea.2021.0099
Citations
16

Abstract (original English)

Injuries of the bone-to-tendon interface, such as rotator cuff and anterior cruciate ligament tears, are prevalent musculoskeletal injuries, yet effective methods for repair remain elusive. Tissue engineering approaches that use cells and biomaterials offer a promising potential solution for engineering the bone-tendon interface, but previous strategies require seeding multiple cell types and use of multiphasic scaffolds to achieve zonal-specific tissue phenotype. Furthermore, mimicking the aligned tissue morphology present in native bone-tendon interface in three-dimensional (3D) remains challenging. To facilitate clinical translation, engineering bone-tendon interface using a single cell source and one continuous scaffold with alignment cues would be more attractive but has not been achieved before. To address these unmet needs, in this study, we develop an aligned gelatin microribbon (μRB) hydrogel scaffold with hydroxyapatite nanoparticle (HA-np) gradient for guiding zonal-specific differentiation of human mesenchymal stem cell (hMSC) to mimic the bone-tendon interface. We demonstrate that aligned μRBs led to cell alignment in 3D, and HA gradient induced zonal-specific differentiation of mesenchymal stem cells that resemble the transition at the bone-tendon interface. Short chondrogenic priming before exposure to osteogenic factors further enhanced the mimicry of bone-carti

What this study does not prove

  • • This study does not prove SVF is an approved treatment or a replacement for standard care.
  • • This is preclinical work; animal or laboratory results cannot be applied to humans.

Evidence level

Evidence from laboratory and animal studies provides groundwork for understanding mechanisms and potential before human studies continue.

How we grade evidence
TendonsHumansDurapatiteGelatinHydrogelsTissue EngineeringCell DifferentiationTissue Scaffolds