Level D· Scientific groundwork from lab and animal studiesLaboratory StudyEurope PMCOpen access

Ammonium ion binding to DNA G-quadruplexes: do electrospray mass spectra faithfully reflect the solution-phase species?

Balthasart F., Plavec J., Gabelica V.

Laboratory Study, published in J Am Soc Mass Spectrom (2013) — summary generated from the PubMed abstract.

Open my reading list
Level D· Scientific groundwork from lab and animal studiesEvidence level of this study

Evidence from laboratory and animal studies provides groundwork for understanding mechanisms and potential before human studies continue.

  • Level A · Stronger Clinical Evidence
  • Level B · Emerging clinical evidence with positive signals
  • Level C · Early human research exploring benefits
  • Level D · Scientific groundwork from lab and animal studies
  • Emerging · Emerging topic under active research
Read the A–D evidence level guide

This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.

Study type
Laboratory Study
Journal
J Am Soc Mass Spectrom (2013)
Reported sample size
—
Source database
Europe PMC
PMID
23132414
PMCID
PMC5110665
DOI
10.1007/s13361-012-0499-3
Citations
63

Abstract (original English)

G-quadruplex nucleic acids can bind ammonium ions in solution, and these complexes can be detected by electrospray mass spectrometry (ESI-MS). However, because ammonium ions are volatile, the extent to which ESI-MS quantitatively could provide an accurate reflection of such solution-phase equilibria is unclear. Here we studied five G-quadruplexes having known solution-phase structure and ammonium ion binding constants: the bimolecular G-quadruplexes (dG(4)T(4)G(4))(2), (dG(4)T(3)G(4))(2), and (dG(3)T(4)G(4))(2), and the intramolecular G-quadruplexes dG(4)(T(4)G(4))(3) and dG(2)T(2)G(2)TGTG(2)T(2)G(2) (thrombin binding aptamer). We found that not all mass spectrometers are equally suited to reflect the solution phase species. Ion activation can occur in the electrospray source, or in a high-pressure traveling wave ion mobility cell. When the softest instrumental conditions are used, ammonium ions bound between G-quartets, but also additional ammonium ions bound at specific sites outside the external G-quartets, can be observed. However, even specifically bound ammonium ions are in some instances too labile to be fully retained in the gas phase structures, and although the ammonium ion distribution observed by ESI-MS shows biases at specific stoichiometries, the relative abundances in solution are not always faithfully reflected. Ion mobility spectrometry results show that all in

What this study does not prove

  • • This study does not prove SVF is an approved treatment or a replacement for standard care.
  • • This is preclinical work; animal or laboratory results cannot be applied to humans.

Evidence level

Evidence from laboratory and animal studies provides groundwork for understanding mechanisms and potential before human studies continue.

How we grade evidence
IonsGasesDNASpectrometry, Mass, Electrospray IonizationModels, MolecularQuaternary Ammonium CompoundsG-Quadruplexes

Browse all related research

Filter the research library by this study's title keywords, author, or publication year.