Level C· Early human research exploring benefitsProspective StudyEurope PMC

Challenges in Perioperative Animal Care for Orthotopic Implantation of Tissue-Engineered Pulmonary Valves in the Ovine Model

Al Hussein H., Al Hussein H., Sircuta C., Cotoi OS., Movileanu I., Nistor D.

Prospective Study on Systemic / IV, published in Tissue Eng Regen Med (2020) — summary generated from the PubMed abstract.

Open my reading list
Level C· Early human research exploring benefitsEvidence level of this study

Early human evidence such as case series or small samples is exploring possible benefits.

  • Level A · Stronger Clinical Evidence
  • Level B · Emerging clinical evidence with positive signals
  • Level C · Early human research exploring benefits
  • Level D · Scientific groundwork from lab and animal studies
  • Emerging · Emerging topic under active research
Read the A–D evidence level guide

This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.

Study type
Prospective Study
Journal
Tissue Eng Regen Med (2020)
Reported sample size
—
Source database
Europe PMC
PMID
32860183
PMCID
PMC7710778
DOI
10.1007/s13770-020-00285-1
Citations
8

Abstract (original English)

Background Development of valvular substitutes meeting the performance criteria for surgical correction of congenital heart malformations is a major research challenge. The sheep is probably the most widely used animal model in heart valves regenerative medicine. Although the standard cardiopulmonary bypass (CPB) technique and various anesthetic and surgical protocols are reported to be feasible and safe, they are associated with significant morbidity and mortality rates. The premise of this paper is that the surgical technique itself, especially the perioperative animal care and management protocol, is essential for successful outcomes and survival. Methods Ten juvenile and adult female sheep aged 7.8-37.5 months and weighing 32.0-58.0 kg underwent orthotopic implantation of tissue-engineered pulmonary valve conduits on beating heart under normothermic CPB. The animals were followed-up for 6 months before scheduled euthanasia. Results Based on our observations, we established a guide for perioperative care, follow-up, and treatment containing information regarding the appropriate clinical, biological, and ultrasound examinations and recommendations for feasible and safe anesthetic, surgical, and euthanasia protocols. Specific recommendations were also included for perioperative care of juvenile versus adult sheep. Conclusion The described surgical technique was feasible, with

What this study does not prove

  • • This study does not prove SVF is an approved treatment or a replacement for standard care.

Evidence level

Early human evidence such as case series or small samples is exploring possible benefits.

How we grade evidence
Pulmonary ValveAnimalsSheepHumansDisease Models, AnimalPerioperative CareHeart Valve Prosthesis ImplantationHeart Valve ProsthesisFemale