Level C· Early human research exploring benefitsCase Report / SeriesEurope PMCOpen access

Cranioplasty and temporal hollowing correction with a three-dimensional printed bioresorbable mesh and double vertical suture anchor muscle sling: a case report

Choi JH., Roh TS., Lee WJ., Baek W.

Case Report / Series on Face & Skin, published in Arch Craniofac Surg (2022) — summary generated from the PubMed abstract.

Open my reading list
Level C· Early human research exploring benefitsEvidence level of this study

Early human evidence such as case series or small samples is exploring possible benefits.

  • Level A · Stronger Clinical Evidence
  • Level B · Emerging clinical evidence with positive signals
  • Level C · Early human research exploring benefits
  • Level D · Scientific groundwork from lab and animal studies
  • Emerging · Emerging topic under active research
Read the A–D evidence level guide

This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.

Study type
Case Report / Series
Journal
Arch Craniofac Surg (2022)
Reported sample size
—
Source database
Europe PMC
PMID
36068693
PMCID
PMC9449094
DOI
10.7181/acfs.2022.00682
Citations
4

Abstract (original English)

Postoperative temporal hollowing is a common complication of craniotomy. Damage and repositioning of the temporalis muscle can lead to a depression in the temporal side of the skull with inferior bulging, worsening aesthetic outcomes. We report a case of cranioplasty with three-dimensional (3D) printed mesh involving an additional correction using a temporalis muscle sling to help address this problem. A 3D-printed bioabsorbable mesh was prepared based on preoperative facial computed tomography, and was fixed to the hollowed area for tissue augmentation. The temporalis muscle was elevated and fanned out to its original position, and a sling was attached to a screw that was fixed to the mesh. For reinforcement, an additional sling was attached to another screw fixed to the mesh 2-3 cm vertically above the first screw. Aesthetic results were confirmed immediately after surgery and later during outpatient follow-up. Both depression and lateral bulging were resolved, and there was no delayed drooping of the temporalis muscle on 6-month follow-up. There were no complications, and the patient was satisfied with the appearance. This is a simple yet effective technique with a low risk of complications, and should be considered for postoperative temporal hollowing patients, especially those with severe lateral bulging.

What this study does not prove

  • • This study does not prove SVF is an approved treatment or a replacement for standard care.
  • • Without an adequate control group, treatment effects cannot be separated from other factors.

Evidence level

Early human evidence such as case series or small samples is exploring possible benefits.

How we grade evidence

Browse all related research

Filter the research library by this study's title keywords, author, or publication year.

Related research