Level C· Early human research exploring benefitsRetrospective StudyEurope PMCOpen access

Diagnostic Accuracy of Five Molecular Assays for the Detection of Dengue Virus

Scarpaleggia M., Garzillo G., Lucente M., Fraccalvieri C., Randazzo N., Massaro E.

Retrospective Study, published in Medicina (Kaunas) (2024) — summary generated from the PubMed abstract.

Open my reading list
Level C· Early human research exploring benefitsEvidence level of this study

Early human evidence such as case series or small samples is exploring possible benefits.

  • Level A · Stronger Clinical Evidence
  • Level B · Emerging clinical evidence with positive signals
  • Level C · Early human research exploring benefits
  • Level D · Scientific groundwork from lab and animal studies
  • Emerging · Emerging topic under active research
Read the A–D evidence level guide

This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.

Study type
Retrospective Study
Journal
Medicina (Kaunas) (2024)
Reported sample size
—
Source database
Europe PMC
PMID
39336598
PMCID
PMC11434457
DOI
10.3390/medicina60091557
Citations
2

Abstract (original English)

Background and Objectives : The steady spread of dengue virus (DENV) poses a profound public health threat worldwide. Reverse transcription real-time polymerase chain reaction (RT2-PCR) has been increasingly recognized as a reference method for the diagnosis of acute dengue infection. The goal of this study was to assess the diagnostic accuracy of five different RT2-PCR kits for the detection of DENV in a historically processed set of sera samples. Materials and Methods : In this retrospective study, 25 sera samples from routinely processed unique adult patients with a known DENV status (previously tested in both molecular and serological assays) were tested in parallel using four conventional (RealStar Dengue PCR Kit 3.0, Clonit'ngo Zika, Dengue & Chikungunya, BioPerfectus Zika Virus/Dengue Virus/Chikungunya Virus Real Time PCR Kit and Novaplex Tropical fever virus) and one sample-to-result (STANDARD M10 Arbovirus Panel) RT2-PCR assays. Additionally, an end-point dilution analysis was conducted in quintuplicate on six serial dilutions of an RNA preparation obtained from a culture-grown DENV serotype 1 strain for a total of 150 tests. Results : The overall accuracy of the evaluated tests ranged from 84% to 100%. In particular, the sensitivity of three conventional RT2-PCR assays (RealStar, Clonit'ngo and Novaplex) was 100% (95% CI: 79.6-100%), while it was lower (73.3%; 95% CI:

What this study does not prove

  • • This study does not prove SVF is an approved treatment or a replacement for standard care.
  • • Without an adequate control group, treatment effects cannot be separated from other factors.

Evidence level

Early human evidence such as case series or small samples is exploring possible benefits.

How we grade evidence
HumansDengue VirusDengueSensitivity and SpecificityRetrospective StudiesAdultReal-Time Polymerase Chain Reaction

Browse all related research

Filter the research library by this study's title keywords, author, or publication year.