Dynamic Rheology for the Prediction of Surgical Outcomes in Autologous Fat Grafting.
Luan A., Zielins ER., Wearda T., Atashroo DA., Blackshear CP., Raphel J.
Animal Study, published in Plast Reconstr Surg (2017) — summary generated from the PubMed abstract.
Evidence from laboratory and animal studies provides groundwork for understanding mechanisms and potential before human studies continue.
- Level A · Stronger Clinical Evidence
- Level B · Emerging clinical evidence with positive signals
- Level C · Early human research exploring benefits
- Level D · Scientific groundwork from lab and animal studies
- Emerging · Emerging topic under active research
This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.
- Study type
- Animal Study
- Journal
- Plast Reconstr Surg (2017)
- Country
- United States
- Reported sample size
- —
- Source database
- PubMed
- PMID
- 28574947
- DOI
- 10.1097/PRS.0000000000003578
- Citations
- 12
Abstract (original English)
Background Because of the abundance and biocompatibility of fat, lipotransfer has become an attractive method for treating soft-tissue deficits. However, it is limited by unpredictable graft survival and retention. Currently, little is known about the viscoelastic properties of fat after various injection methods. Here, the authors assess the effects of cannula diameter, length, and shape on the viscoelastic properties, structure, and retention of fat. Methods Human lipoaspirate was harvested using suction-assisted liposuction and prepared for grafting. A syringe pump was used to inject fat at a controlled flow rate through cannulas of varying gauges, lengths, and shapes. Processed samples were tested in triplicate on an oscillatory rheometer to measure their viscoelastic properties. Fat grafts from each group were placed into the scalps of immunocompromised mice. After 8 weeks, graft retention was measured using micro-computed tomography and grafts were explanted for histologic analysis. Results Lipoaspirate injected through narrower, longer, and bent cannulas exhibited more shear thinning with diminished quality. The storage modulus (G') of fat processed with 18-gauge cannulas was significantly lower than when processed with 14-gauge or larger cannulas, which also corresponded with inferior in vivo histologic structure. Similarly, the longer cannula group had a significantly
What this study does not prove
- • This study does not prove SVF is an approved treatment or a replacement for standard care.
- • This is preclinical work; animal or laboratory results cannot be applied to humans.
Evidence level
Evidence from laboratory and animal studies provides groundwork for understanding mechanisms and potential before human studies continue.
How we grade evidenceBrowse all related research
Filter the research library by this study's title keywords, author, or publication year.