Level A· Stronger Clinical EvidenceSystematic ReviewEurope PMCOpen access

Near-infrared fluorescence image-guidance in plastic surgery: A systematic review

Cornelissen AJM., van Mulken TJM., Graupner C., Qiu SS., Keuter XHA., van der Hulst RRWJ.

Systematic Review with a reported sample of 1166 on Systemic / IV, published in Eur J Plast Surg (2018) — summary generated from the PubMed abstract.

Open my reading list
Level A· Stronger Clinical EvidenceEvidence level of this study

Relatively higher-quality human studies compared with other topics in this database, e.g. multiple RCTs or systematic reviews. This does not mean it is standard or approved care.

  • Level A · Stronger Clinical Evidence
  • Level B · Emerging clinical evidence with positive signals
  • Level C · Early human research exploring benefits
  • Level D · Scientific groundwork from lab and animal studies
  • Emerging · Emerging topic under active research
Read the A–D evidence level guide

This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.

Study type
Systematic Review
Journal
Eur J Plast Surg (2018)
Reported sample size
1166
Source database
Europe PMC
PMID
29780209
PMCID
PMC5953995
DOI
10.1007/s00238-018-1404-5
Citations
42

Abstract (original English)

Background Near-infrared fluorescence (NIRF) imaging technique, after administration of contrast agents with fluorescent characteristics in the near-infrared (700-900 nm) range, is considered to possess great potential for the future of plastic surgery, given its capacity for perioperative, real-time anatomical guidance and identification. This study aimed to provide a comprehensive literature review concerning current and potential future applications of NIRF imaging in plastic surgery, thereby guiding future research. Methods A systematic literature search was performed in databases of Cochrane Library CENTRAL, MEDLINE, and EMBASE (last search Oct 2017) regarding NIRF imaging in plastic surgery. Identified articles were screened and checked for eligibility by two authors independently. Results Forty-eight selected studies included 1166 animal/human subjects in total. NIRF imaging was described for a variety of (pre)clinical applications in plastic surgery. Thirty-two articles used NIRF angiography, i.e., vascular imaging after intravenous dye administration. Ten articles reported on NIRF lymphography after subcutaneous dye administration. Although currently most applied, general protocols for dosage and timing of dye administration for NIRF angiography and lymphography are still lacking. Three articles applied NIRF to detect nerve injury, and another three studies described o

What this study does not prove

  • • This study does not prove SVF is an approved treatment or a replacement for standard care.

Evidence level

Relatively higher-quality human studies compared with other topics in this database, e.g. multiple RCTs or systematic reviews. This does not mean it is standard or approved care.

How we grade evidence

Browse all related research

Filter the research library by this study's title keywords, author, or publication year.