Review of Autologous Fat Grafting in Postmastectomy Reconstruction Patients: Nonroutine Diagnostics and Oncologic Safety
Sayyed AA., Perez-Alvarez IM., Singh T., King CA., Welschmeyer AF., Bartholomew AJ.
Retrospective Study with a reported sample of 155, published in Plast Reconstr Surg Glob Open (2022) — summary generated from the PubMed abstract.
Early human evidence such as case series or small samples is exploring possible benefits.
- Level A · Stronger Clinical Evidence
- Level B · Emerging clinical evidence with positive signals
- Level C · Early human research exploring benefits
- Level D · Scientific groundwork from lab and animal studies
- Emerging · Emerging topic under active research
This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.
- Study type
- Retrospective Study
- Journal
- Plast Reconstr Surg Glob Open (2022)
- Reported sample size
- 155
- Source database
- Europe PMC
- PMID
- 36320622
- PMCID
- PMC9616633
- DOI
- 10.1097/gox.0000000000004579
- Citations
- 3
Abstract (original English)
Autologous fat grafting (FG) is increasingly used as an adjunctive reconstruction technique to augment volume, achieve symmetry, and improve contour deformities. This study aims to characterize the oncologic and surgical safety of FG in women undergoing autologous breast reconstruction (ABR) or implant-based reconstruction (IBR). Methods A retrospective chart review was performed for all patients undergoing FG at a multi-site single health system between 2015 to 2018. A total of 228 eligible breasts from 155 patients were identified using Current Procedural Terminology codes. Patients were divided by reconstructive technique. Bivariate analyses compared baseline characteristics and post-FG outcomes. Results Mean age for patients undergoing ABR (129 breasts) was 52.8 years compared to 48.6 years for those undergoing IBR (99 breasts; P = 0.002). A heavier volume of fat was grafted per ABR breast (143.8mL) than per IBR breast (102.2mL; P = 0.002). Forty-seven (20.6%) breasts required FG revision, more frequently in ABR breasts (31.0%) than IBR breasts (7.1%; P Conclusion FG is a safe, surgically simple procedure more commonly performed in ABR breasts. FG use in ABR and IBR breasts is oncologically safe, with no impairment in breast surveillance and low rates of locoregional recurrence, but possibly increased incidence of nonroutine imaging and biopsies.
What this study does not prove
- • This study does not prove SVF is an approved treatment or a replacement for standard care.
- • Without an adequate control group, treatment effects cannot be separated from other factors.
Evidence level
Early human evidence such as case series or small samples is exploring possible benefits.
How we grade evidenceBrowse all related research
Filter the research library by this study's title keywords, author, or publication year.