Studies in fat grafting: Part II. Effects of injection mechanics on material properties of fat.

Atashroo D., Raphel J., Chung MT., Paik KJ., Parisi-Amon A., McArdle A.

Prospective Study, published in Plast Reconstr Surg (2014) — summary generated from the PubMed abstract.

Open my reading list
Level C· Early human research exploring benefitsEvidence level of this study

Early human evidence such as case series or small samples is exploring possible benefits.

  • Level A · Stronger Clinical Evidence
  • Level B · Emerging clinical evidence with positive signals
  • Level C · Early human research exploring benefits
  • Level D · Scientific groundwork from lab and animal studies
  • Emerging · Emerging topic under active research
Read the A–D evidence level guide

This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.

Study type
Prospective Study
Journal
Plast Reconstr Surg (2014)
Country
United States
Reported sample size
—
Source database
PubMed
PMID
25028817
PMCID
PMC4101917
DOI
10.1097/PRS.0000000000000289
Citations
23

Abstract (original English)

Background Although fat grafting can address many soft-tissue deficits, results remain inconsistent. In this study, the authors compared physical properties of fat following injection using an automated, low-shear device or the modified Coleman technique. Methods Lipoaspirate was obtained from nine patients and processed for injection using either a modified Coleman technique or an automated, low-shear device. Fat was passed through a 2-mm cannula and compared with minimally processed fat. A rheometer was used to measure the storage modulus and shear rate at which tissues began to lose their solid-like properties. Viscosity was also measured, and gross properties of treatment groups were evaluated qualitatively with a glass slide test. Results Fat injected through an automated, low-shear device closely matched physical properties of minimally processed fat. The storage modulus (G') of fat for the device group was greater than for the modified Coleman group, and the onset of breakdown was delayed. Similarly, viscosity measurement of fat from the automated device closely matched minimally processed fat and was greater than that of othe modified Coleman group. Conclusions The physical properties of lipoaspirate processed using an automated, low-shear device with a 2-mm cannula preserved the intactness of fat more than the modified Coleman technique. The authors' rheologic data dem

What this study does not prove

  • • This study does not prove SVF is an approved treatment or a replacement for standard care.

Evidence level

Early human evidence such as case series or small samples is exploring possible benefits.

How we grade evidence
Adipose TissueBiomechanical PhenomenaHumansInjections

Browse all related research

Filter the research library by this study's title keywords, author, or publication year.