Level C· Early human research exploring benefitsProspective StudyEurope PMCOpen access

Fat Graft Size: Relationship Between Cannula and Needle Diameters

Vazquez OA., Markowitz MI., Becker H.

Prospective Study on Hip, published in Cureus (2020) — summary generated from the PubMed abstract.

Open my reading list
Level C· Early human research exploring benefitsEvidence level of this study

Early human evidence such as case series or small samples is exploring possible benefits.

  • Level A · Stronger Clinical Evidence
  • Level B · Emerging clinical evidence with positive signals
  • Level C · Early human research exploring benefits
  • Level D · Scientific groundwork from lab and animal studies
  • Emerging · Emerging topic under active research
Read the A–D evidence level guide

This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.

Study type
Prospective Study
Journal
Cureus (2020)
Reported sample size
—
Source database
Europe PMC
PMID
32399332
PMCID
PMC7212710
DOI
10.7759/cureus.7598
Citations
7

Abstract (original English)

Background It is generally believed that trauma to fat grafts is detrimental and affects the survival of the graft. In addition, it has been shown that smaller fat particle size corresponds to better survival; however, smaller cannula openings correspond to slower and more difficult fat graft harvesting. Objectives This study documents the relationship between cannula size, harvested fat cell size, and injection needle size. A means of reducing fat particle size following aspiration with larger diameter cannulas is also discussed. Methods Fat was harvested from five patients undergoing elective liposuction. Each fat sample was placed in a syringe and injected through progressively smaller needles until obstruction under low pressure was obtained. The minimal needle size was documented for each sample. Results Fat harvested with a liposuction cannula results in different size fat particles ranging up to the size of the cannula. Particles obtained from 3- and 4-mm cannulas can be injected without obstruction through a 16-gauge needle. Particles obtained from a 2-mm cannula can be injected without obstruction through an 18-gauge needle. Particles obtained from a 1-mm cannula can be injected without obstruction through a 20-gauge needle. Particles obtained from a 1-mm cannula could not be injected without obstruction through a 22-gauge needle. Conclusions There is a relationship be

What this study does not prove

  • • This study does not prove SVF is an approved treatment or a replacement for standard care.