Ultrasound-assisted biofabrication and bioprinting of preferentially aligned three-dimensional cellular constructs.
Chansoria P., Narayanan LK., Schuchard K., Shirwaiker R.
Laboratory Study on Meniscus Injury, published in Biofabrication (2019) — summary generated from the PubMed abstract.
Evidence from laboratory and animal studies provides groundwork for understanding mechanisms and potential before human studies continue.
- Level A · Stronger Clinical Evidence
- Level B · Emerging clinical evidence with positive signals
- Level C · Early human research exploring benefits
- Level D · Scientific groundwork from lab and animal studies
- Emerging · Emerging topic under active research
This page is generated from the PubMed record. The Thai description is an automated summary of bibliographic fields and the abstract, not a full translation, and is not medical advice.
- Study type
- Laboratory Study
- Journal
- Biofabrication (2019)
- Country
- England
- Reported sample size
- —
- Source database
- PubMed
- PMID
- 30943460
- DOI
- 10.1088/1758-5090/ab15cf
- Citations
- 34
Abstract (original English)
A critical consideration in tissue engineering is to recapitulate the microstructural organization of native tissues that is essential to their function. Scaffold-based techniques have focused on achieving this via the contact guidance principle wherein topographical cues offered by scaffold fibers direct migration and orientation of cells to govern subsequent cell-secreted extracellular matrix organization. Alternatively, approaches based on acoustophoretic, electrophoretic, photophoretic, magnetophoretic, and chemotactic principles are being investigated in the biofabrication domain to direct patterning of cells within bioink constructs. This work describes a new acoustophoretic three-dimensional (3D) biofabrication approach that utilizes radiation forces generated by superimposing ultrasonic bulk acoustic waves (BAW) to preferentially organize cellular arrays within single and multi-layered hydrogel constructs. Using multiphysics modeling and experimental design, we have characterized the effects of process parameters including ultrasound frequency (0.71, 1, 1.5, 2 MHz), signal voltage amplitude (100, 200 mVpp), bioink viscosity (5, 70 cP), and actuation duration (10, 20 min) on the alignment characteristics, viability and metabolic activity of human adipose-derived stem cells (hASC) suspended in alginate. Results show that the spacing between adjacent cellular arrays decrea
What this study does not prove
- • This study does not prove SVF is an approved treatment or a replacement for standard care.
- • This is preclinical work; animal or laboratory results cannot be applied to humans.
Evidence level
Evidence from laboratory and animal studies provides groundwork for understanding mechanisms and potential before human studies continue.
How we grade evidenceBrowse all related research
Filter the research library by this study's title keywords, author, or publication year.
Related research
- Level ASystematic ReviewEurope PMC
Optimizing Meniscus Allograft Transplantation - Reducing Extrusion and Restoring Joint Loading Mechanics: A Systematic Review
Systematic Review on Osteoarthritis, Meniscus Injury, published in Curr Rev Musculoskelet Med (2026) — summary generated from the PubMed abstract.
- 2026
Curr Rev Musculoskelet Med - Level ASystematic ReviewEurope PMC
Emerging biologic augmentation strategies for meniscal repair: a systematic review
Systematic Review with a reported sample of 18 on Meniscus Injury, Chronic Wound, published in BMC Musculoskelet Disord (2024) — summary generated from the PubMed abstract.
- 2024
- n = 18
BMC Musculoskelet Disord7 citations - Level ASystematic ReviewEurope PMC
Osteoarthritis After Anterior Cruciate Ligament Reconstruction: A Systematic Review of Contributing Factors and Potential Treatments
Systematic Review on Osteoarthritis, Meniscus Injury, Ligament Injury, published in Cureus (2024) — summary generated from the PubMed abstract.
- 2024
Cureus1 citations - Level ASystematic ReviewPubMed
Cell-based therapies have disease-modifying effects on osteoarthritis in animal models. A systematic review by the ESSKA Orthobiologic Initiative. Part 1: adipose tissue-derived cell-based injectable therapies.
Systematic Review on Osteoarthritis, Meniscus Injury, published in Knee Surg Sports Traumatol Arthrosc (2022) — summary generated from the PubMed abstract.
- 2022
Knee Surg Sports Traumatol Arthrosc40 citations - Level ASystematic ReviewPubMed
Cell-based therapy in soft tissue sports injuries of the knee: a systematic review.
Systematic Review with a reported sample of 9 on Osteoarthritis, Meniscus Injury, Tendon Injury, Ligament Injury, published in Expert Opin Biol Ther (2021) — summary generated from the PubMed abstract.
- 2021
- n = 9
Expert Opin Biol Ther10 citations - Level ASystematic ReviewPubMed
Stem cells application in meniscal tears: a systematic review of pre-clinical and clinical evidence.
Systematic Review on Meniscus Injury, published in Eur Rev Med Pharmacol Sci (2021) — summary generated from the PubMed abstract.
- 2021
Eur Rev Med Pharmacol Sci